Main Switchboard

By |October 28th, 2016|ELECTRIC|0 Comments

I have not posted in a while again. Kiting season has started too, so have to be even more efficient with my time. Finished the main switchboard. Below is a picture from my internal installation documentation. It is a website running on the central system of the van with all information about components, connectors, serviceable parts, cable routing, fuses and positions etc.

Below is a connector for the 12v coil cables of the latching relays in the main board and the energy meter signal outputs. Documentation is not yet finished for the installation site. Will be similar to the image […]

DC Contactors

By |October 19th, 2016|MATERIAL SOURCES|0 Comments

I get asked frequently where I source my material and components and as a consequence I will add a few posts to this category to help others finding special items. Generally I buy 95% of my components and materials from Ebay with sources mainly in Hong Kong and mainland China. Rarely I buy something through Ebay from an Australian source. All the items which are offered on Ebay Australia are available directly from China for a fraction of the price. I also use sources in the US which are faster than China and mostly faster than Australian sources from […]

More Lighting

By |October 12th, 2016|BUILD, ELECTRIC|0 Comments

Last week I also completed the lighting in the living area. The down lights above the dinner table. the indirect lighting at the ceiling and around the slide out. I also installed a light strip as a reading light.

For the ceiling light I use two switches coded to the same controller. One at the entry door and one on the wall to the bedroom. These switches are RF, they do not require cables. Have them from China through Ali Express but they are no longer available there I recently discovered. What a pity, great concept. Found it on […]

More Electrical Work

By |October 12th, 2016|BUILD, ELECTRIC|0 Comments

Last week I finally received the 6mm bootlace ferrules for the larger 240V cable. Had ordered them from Hong Kong, 5.95 for 200 with free shipping. Here in Australia the 200 would be $40, what a joke.

Connected the inverter outputs now and the input board as well as the kitchen board.

The kitchen board is fully connected now.

So is the input board. This protects the inverter input and combines the inverter outputs. Also supplies the transfer switch of the small inverter.

Clean Up

By |October 12th, 2016|Uncategorized|0 Comments

Have not posted for a while. Was really busy with several things. Had to finish wedding photos, album and slide shows for a friends wedding which I had taken a while ago. That took me quite a few hours. The next project was a 4 day cleanup of our slide-on camper. It was going to my daughters property as additional guest accommodation for clinics and workshops.

I removed all electric and electronic installations which are not required anymore. Was a fair amount of cables, switches and devices I had in there. Solar charger, battery charger, solar panels, screen mounting arms, […]

AC Distribution

By |September 29th, 2016|BUILD, ELECTRIC|0 Comments

Over the last 2 weeks I have installed the AC switchboards. There is more to it than just a few images.The scope of the system far exceeds the content of a few posts on the website. Important to mention is that all breakers are double pole as required for portable structures. I have contactors to isolate the subboard when not needed to avoid unwanted standby currents.

I also use power meters with Modbus interface to monitor consumption of the air condition and the fridge. I also use RVDs additionally to RCDs. This is subject for another post.

The main switchboard above […]

12V Installation

By |September 29th, 2016|BUILD, ELECTRIC|0 Comments

This week the large battery lugs arrived. I had plenty of B&S 0 but no B&S 00, which I had ordered. The main supply is B&S 00 from the batteries to the first distribution point. From here the 12V supply runs down towards the chassis battery and also to the inside. Both lines are B&S 0. At the main distribution point I also connected the small inverter.  A total of 3 big fuses are installed. Each connection is colour coded and the three fuses are connected with a bus bar I made from flat copper.

I also started to box in […]

Audio/Video System

By |September 29th, 2016|BUILD, ELECTRIC|0 Comments

Last week I have received a Mini Pc  had ordered as a sample. It is meant to be driving the audio system and will be mounted close to the Logitech amplifier. I have designed the entertainment system around the old Logitech system I had in the slide-on camper. I really liked it, fairly compact subwoofer and several inputs including an optical digital input. I also will have a video server connected to the TV via HDMI 2.0 for full UHD 4K transmission. The HDMI cable runs back to a HDMI to Toslink converter for surround sound input into the […]

Ceiling Fan

By |September 28th, 2016|BUILD, ELECTRIC, INTERIOR BUILD|0 Comments

A couple of days ago I installed a ceiling fan in the living area. The fan is a DC motor fan, which is very quiet and efficient, far more than AC motors. It is a 6 speed and can move a lot more air than 4 or 5 small 12V fans and still don’t need more power. I connect the fan to the small inverter and we can run it when the air condition is not needed. We will also run it when we heat with the split system to get the warm air down from the ceiling. This […]

Power Input Continued

By |September 28th, 2016|BUILD, ELECTRIC, INTERIOR BUILD|0 Comments

I made the box with the power inlets earlier. Next I fitted the rear wall to mount the small switchboard to accommodate the relays required for the input selector.

 

 

The switchboard with four relays is mounted to be connected to the supply lines to the inverters.

The box is put in place inside the battery compartment and the supply cables are connected.

The switchboard is closed. This is the first component completely finished now.

 

 

 

The input selector is used to allow one or two supply lines to be connected. If only one lead is connected to the black connector a cross connection is […]

Electrical 12V

By |September 28th, 2016||0 Comments

All about battery installation and 12V wiring

Electrical 240V

By |September 28th, 2016||0 Comments

All electrical installation images

Gutter

By |September 11th, 2016|BODY BUILD, BUILD|0 Comments

This is the front of the van after a few weeks of rain and not having a cover anymore. Lots of sticky stuff from the trees and dirt washed off the roof down the front. I should have installed some gutters a long time ago to let the water flow off to the side and not wash all the dirt onto the baggage doors. The little service door for the power inlets caught a lot of dirt and I want to keep the water away from it especially when power cords are connected.

I have plastic gutters, self adhesive, to […]

Power Input

By |September 11th, 2016|BUILD, ELECTRIC, INTERIOR BUILD|0 Comments

The van has 3 power inlets. Two 15 amp inlets, each connected to one of the larger inverters, and one 10 amp connector meant to be used for the smaller inverter when no 15 amp connection is available. The supply for the smaller inverter can be switched between the 10 amp and a 15 amp supply. All three inverters have an automatic transfer switch for the AC input.

 

I have two different colour inputs. The black one also supplies the input for the smaller inverter. The inlets are placed behind a service door with openings for two leads. When the AC […]

Inverter Placement

By |September 11th, 2016|BUILD, INTERIOR BUILD|0 Comments

Over the last week I prepared a mounting base for the inverters in the battery compartment. The inverters are meant to hang on a wall for best ventilation, however they are 18kg each and the wall is an aluminium honeycomb panel, which may not hold the weight on rough roads. I decided to make a support, which allows for ventilation and solid support.

The support is built from the composite panel of the body cutouts.

I glued it together, made the required cuts for the cables and painted it.

After the paint dried I placed the support inside the battery compartment and mounted […]

Catch Up Post

By |September 5th, 2016|BUILD, INTERIOR BUILD|0 Comments

Since the last post about the cables I had done a lot of little things, most days for a few hours before I worked on my commercial project. This post shows mainly images of the things I have done. Facebook readers will not really have much to see from this post since only one image is copied to Facebook for each post.

More cables going in. I mark each cable with a tag.

This helps later to identify the cables when they get connected to the switchboards

I use three different types of cables in three colours, The main supply is 4 sqmm in orange, […]

Work Area Finished

By |September 5th, 2016|BUILD, INTERIOR BUILD|0 Comments

Almost, at least. The only thing left is the blind. Finished the pelmet the shelves and the cover for the cable channels.

Installed the lights and  switch for the indirect lighting around the work desk.

The blind is next when the motor I ordered arrives.

Audio System

By |September 5th, 2016|BUILD, INTERIOR BUILD|0 Comments

Amongst other things I have started to connect some components of the main audio system. I will make another “catch up” post  with lots of images after this one.

I use an old Logitech 5.1 audio system, which I had in the slide-on camper since 2007. It is still good, has a great subwoofer and is compact with the built in amp and the remote head unit. I really like it, all the newer ones never worked as good as this one and I did not want to use a full domestic stereo.

Originally I had decided to use the Logitech speakers […]

Routing Cables

By |August 16th, 2016|BUILD, ELECTRIC, INTERIOR BUILD|0 Comments

The general concept for my electrical installation is that I can access any cable, connection or any electrical component easily without removing half of the cabinets. One aspect which needs a bit more attention to hide the cables are the slide-outs. Cables can only come into a slide-out close to the inside corner and one needs to leave enough length of all cables that they are long enough when the slide-out comes in but also fold out of sight when the slide-out goes out. Each of the slide-outs requires a slightly different approach to achieve this. The cabinet to the […]

Main DC Fuses Installed

By |August 12th, 2016|BUILD, ELECTRIC, INTERIOR BUILD|0 Comments

Today we had finally some better weather. No rain and it warmed up a bit, so it was pleasant to work outside. I continued to bolt down the batteries. The washers had arrived a few days earlier and I put all the bolts in and fixed the batteries. They will not go anywhere in a hurry. Before they move the van will disintegrate.

Mounted the shunt for the battery monitor onto the battery casing. That is the most solid point and easy accessible. I use a 1000A shunt. The standard 500A is not sufficient for this installation.